Input voltage: (Standard kit option) 230v AC, 50Hz-60Hz
Primary supply to the electric motor: ACDC Power Pack with battery as back-up only (24V, 3.5Ah)
Max duty cycle (work rate) with mains present: 98%
Number of operations on battery reserve without AC mains present: 100 within the first 24h of power failure
Maximum gate mass: 450kg (<4.7m leaf)
Maximum gate leaf length applicable to performances specified here: 6m (<225kg mass)
Rated gate load: 1900N
Rated gate speed:† 27mm/sec
Typical operating time through 90°**: <19 seconds
Built-in receiver: 434MHz, 4 channel, ET BLU MIX® Enhanced rolling code. 32 user capacity